Standalone Hybrid Power Generation Syste

 
Standalone hybrid generation system for the remote area of Thar, Pakistan
 
 
 
Where Cp is the fraction of upstream wind power captured by the rotor blades, also called as power 
coefficient of the rotor or the rotor efficiency, expressed as: 
2.19 
Cp depends on vo/v ratio and is a single (theoretical) maximum value function whose value varies 
between (0.59 – 0.2) depending on the type of turbines i.e. Cp value of less than 0.5 for high speed, 2-
pole turbine and Cp value between 0.2 and 0.4 for low speed with more blades are commonly used 
[11, 23]. 
Fig.2.8: Rotor efficiency as a function of vo/v ratio[11] 
The total (actual) amount of wind energy that passes area Arot by wind speed V is [22, 23]: 
2.20 
Where
Cp = coefficient of performance (0.59 – 0.35 depending on the turbine types).
η
g= efficiency of generator. 
η
gb = gearbox/bearings efficiency.
A general characteristic curve that describes the wind turbine output power variation with steady wind 
speed is shown in Figure 2.9 below [24]. 
Fig. 2-9: Typical wind turbine power output with steady wind speed characteristics [24] 


 
Standalone hybrid generation system for the remote area of Thar, Pakistan
 
 
 
From the above characteristic curve, there are three important points at which much attention is paid 
for the speeds and the corresponding turbine output powers for every wind turbine. These are the cut-
in speed, rated output speed and cut-out speed. The important terms characterizing the turbine power-
speed (Figure 2-9) characteristics are described below.
Cut-in speed A very low wind normally exerts insufficient torque on the wind turbine blades to make 
them rotate. When the speed increases, the wind turbine starts rotating and generating electrical 
power. The speed at which the turbine first starts to rotate is called the cut-in speed and is typically 
between 3 and 4 m/s [24].