The art of air blast freezing Design and
LEO PHAM, Document, Email sample
SH,NTU
. The initial guess of the fraction of the tube
length required for desuperheating, F
SH
, is iterated until UA
SH,model
and UA
SH,NTU
converge. Upon convergence, the fraction of tube
length required for desuperheating is known and the process is
repeated for the two-phase section.
The two-phase zone analysis starts by guessing the fraction of
the tube length required for full refrigerant condensation (latent
heat), F
2Ph
. The resistances are solved for the tube length L
2Ph
cor-
responding to F
2Ph
. The refrigerant saturation temperature and the
HSC discharge pressure are used to determine the refrigerant
properties. The average heat transfer coefficient during condensa-
tion in horizontal tubes, required to determine the refrigerant-side
resistance in the two-phase zone, is calculated using the correlation
suggested by Dobson and Chato
[53]
. The refrigerant side resistance
is determined with the area corresponding to the two-phase
length, L
2Ph
. The resistances are calculated in the same manner as
described for the superheated region using L
2Ph
. The conductance of
the two-phase zone, as calculated by the model, is given by:
UA
2Ph;model
¼ N
tubes
$
1
R
total;2Ph
(11)
The actual rate of heat transfer over the two-phase zone, _q
2Ph
, is
calculated by:
_q
2Ph
¼ _
m
3
ðh
x¼1
h
x¼0
Þ
(12)
where h
x¼1
and h
x¼0
refer to the vapour and liquid saturation
enthalpies respectively. The air-side capacitance rate is the
minimum capacitance rate in the condensing section as the
capacitance rate of the condensing refrigerant is effectively infinite.
Therefore, the maximum possible heat transfer rate in the
condensing zone is:
_q
max;2Ph
¼ _C
air;sat
T
R;sat
T
air;in

(13)
The NTU conductance, UA
2Ph,NTU
, is calculated by:
UA
2Ph;NTU
¼ N
tubes
_C
minNTU2Ph
(14)
P. Dempsey, P. Bansal / Applied Thermal Engineering 41 (2012) 71e83
77


The initial guess of the tube length required for the two-phase
region F
2Ph
is iterated until UA
2Ph,model
and UA
2Ph,NTU
converge.
Upon convergence, the fraction of tube length required for phase-
change is known and the process is repeated for the sub-cooled zone.
With F
SH
and F
2Ph
known, the fraction of tube length associated
to sub-cooling is calculated by:
F
SC
¼ 1
F
SH
F
2Ph
(15)
The six resistances are calculated using the sub-cooling tube
length given by:
L
tube;SC
¼ F
SC
$L
tube;total
(16)
The conductance of the sub-cooled zone is calculated by:
UA
SC;model
¼ N
tubes
$
1
R

tải về 1.05 Mb.