C157

C 157/C 157M – 08
2
Copyright by ASTM Int'l (all rights reserved); Thu Apr 16 06:09:51 EDT 2009
Downloaded/printed by
Laurentian University pursuant to License Agreement. No further reproductions authorized.


FIG. 1 Atmometer
C 157/C 157M – 08
3
Copyright by ASTM Int'l (all rights reserved); Thu Apr 16 06:09:51 EDT 2009
Downloaded/printed by
Laurentian University pursuant to License Agreement. No further reproductions authorized.


ASTM C 157 FIGURES
Figure Di-
mensions
SI Units
Inch-Pound Units
A
Adjustable torque handle
Adjustable torque handle
1.4–1.7 Nm
12–15 in.lb
B
Jam nut
Jam nut
10–15 IMC
3

8
-in.–16 NC
C
10-mm diameter 1.5 IMC Thd.
3

8
-in. dia–16 NC Thd.
D
12-mm diameter 1.5 IMC Thd.
1

2
-in. dia–20 NC Thd.
E
64-mm diameter
2.50-in. diameter
F
64-mm diameter
2.50-in. diameter
G
57-mm diameter
2.25-in. diameter
H
52-mm diameter
2.06-in. diameter
I
51-mm diameter
2.00-in. diameter
J
14 mm
0.56 in.
K
8 mm
0.31 in.
L
13 mm
0.50 in.
M
3 mm
0.125 in.
N
8 mm
0.31 in.
O
19 mm
0.75 in.
P
32 mm
1.25 in.
Q
53 mm
2.06 in.
R
1.5-mm drill through 11.5-mm C’
drill
1

16
-in. drill through
29

64
-in. C’ drill
32-mm deep tap 12-mm 1.5-mm
IMF Thd
1
1

4
-in. deep tap
1

2
-in.–20 Thd
S
19 mm deep 16 mm C’ bore 6
mm deep
3

4
-in. deep
5

8
-in. C’ bore
1

4
in.
deep
T
5-mm drill 3-mm deep C’ drill
3

16
-in. drill
1

8
-in. deep C’ drill
at 60° as shown
at 60° as shown
through to center tapped hole
through to center tapped hole
U
3 mm
0.12 in. diameter
V
2 mm
0.09 in.
W
10 mm
0.40 in.
X
60 mm
2.36 in.
Y
35 mm
1.37 in.
Z
6 mm
0.25 in.
AA
6 mm
0.25 in.
BB
4 mm
0.15 in.
CC
6 mm
0.25 in.
DD
23 mm
0.87 in.
EE
38 mm
1.50 in.
FF
25 to 75 mm
1 to 3 in.
GG
35 mm high
1.37 in. high
HH
100 mm
4 in.
II
130 mm
5 in.
JJ
8 cm–6.1 kg/m channel
3 in.–4.1 lb/ft channel
KK
20 mm
3

4
in.
LL
330 mm
13 in.
MM
14–2.0 IMC Thd.
1

2
in.–12 Thd.
NN
20 mm
3

4
in.
OO
50 mm
2 in.
PP
20 mm
3

4
in.
QQ
60 mm
1

4
in.
RR
10 mm
3

8
in.
SS
Drill Cl. hole for
Drill Cl. hole for
4.5–0.75 IMC machine screw
8–32 in. machine screw
TT
13 mm
1

2
in.
UU
25 mm
1 in.
VV
30 mm
1-
3

16
in.
WW
60 mm
2-
3

8
in.
XX
12.5 mm
1

2
in.
YY
6-mm diameter steel rod
1

4
-in. diameter steel rod
ZZ
4.5–0.75 IMC 3 16-mm machine
screw
8–32 3
5

8
-in. machine screw
6. Sampling
6.1 Take samples according to the applicable provisions of
Practice
C 192/C 192M
from batches of hydraulic-cement
mortar or concrete made in the laboratory (
Note 2
).
N
OTE
2—When collecting samples in nonstandard conditions, such as
field concrete, it is suggested that Practice
C 172
be followed. Field cast
specimens can show up to twice as much drying shrinkage as laboratory
cast specimens from the same materials and proportions.
FIG. 2 Atmometer Assembly
Instructions for Use—Remove the end and the outer side plates leaving the
base, center side plate, and gage stud holders in place. Engage the machine
screw in the drilled and tapped end of the center side plate. Turn the thumbscrew
to loosen the bars.
FIG. 3 Device for Detaching 1-in. [25-mm] Square by 11
1

4
-in.
[285-mm] Bars from Center Side Plate of Double Molds
N
OTE
—Dimensions shown are appropriate for one design of mold for
3-in. [75-mm] square specimens. Change dimensions as required for other
molds.
FIG. 4 Device for Demolding Specimens from Single Molds
C 157/C 157M – 08
4
Copyright by ASTM Int'l (all rights reserved); Thu Apr 16 06:09:51 EDT 2009
Downloaded/printed by
Laurentian University pursuant to License Agreement. No further reproductions authorized.


7. Test Specimens
7.1 Mortar—The test specimen for mortar shall be a prism
of 1-in. [25-mm] square cross-section and approximately 11
1

4
in. [285 mm] in length. Three specimens shall be prepared for
each test condition.
7.2 Concrete—The test specimen for concrete, in which all
of the aggregate passes a 2-in. [50-mm] sieve, shall be a prism
of 4-in. [100-mm] square cross-section and approximately 11
1

4
in. [285 mm] long. However, a prism of 3-in. [75-mm] square
cross-section shall be used if all of the aggregate passes a 1-in.
sieve [25.0-mm]. Three specimens shall be prepared for each
test condition. Since length change is capable of being influ-
enced by the size of the specimen, specimens to be compared
shall have the same dimensions, and any specification limit
based upon this method shall be applied to a specified size of
specimen.