Designation: c 157/C 157M – 08 Standard Test Method for Length Change of Hardened Hydraulic-Cement Mortar and Concrete 1


 Procedure for Calculating Length Change



tải về 128.58 Kb.
Chế độ xem pdf
trang8/10
Chuyển đổi dữ liệu31.01.2024
Kích128.58 Kb.
#56513
1   2   3   4   5   6   7   8   9   10
C157

12. Procedure for Calculating Length Change
12.1 Comparator Reading—Read the comparator dial with
the test specimen in the comparator; then read the comparator
dial with the reference bar in the comparator. Calculate the
difference between the two readings as described in Practice
C 490
.
12.2 Length Change—Calculate the length change of any
specimen at any age after the initial comparator reading as
follows:
DL
x
5
CRD 2 initial CRD
G
3
100
(1)
where:
DL
x
= length change of specimen at any age, %,
CRD = difference between the comparator reading of the
specimen and the reference bar at any age, and
G
= the gage length (10 in. [250 mm]) (see
Note 4
).
N
OTE
4—In Practice
C 490
, the comparator dial gage specified for use
with 10-in. gage length specimens shall be graduated in fractions of an
inch; the comparator dial gage specified for use with 250-mm gage length
specimens shall be graduated in fractions of a millimetre.
13. Report
13.1 Report the following information:
13.1.1 Identification as mortar or concrete specimens, num-
ber of specimens for each condition, and date molded,
13.1.2 Source and identification of each material employed,
13.1.3 Type, maximum size, moisture condition, and grad-
ing of the aggregate,
13.1.4 Size of specimens,
13.1.5 Mortar or concrete mixture data at time of mixing,
including flow or slump and temperature of mixture,
13.1.6 Description of consolidation of concrete, specifying
whether rodding or external vibration was used,
13.1.7 Conditions and periods of moist curing prior and
subsequent to removal of molds, if different from those
specified,
13.1.8 Description of storage condition, including tempera-
ture and humidity, either by indicating whether the water or air
storage was followed or by giving the details of any procedure
not conforming to either of these conditions,
13.1.9 Total elapsed time of storage and total age of
specimen, or total elapsed time of curing and storage if the
same condition was used for both,
13.1.10 Length change data, reported as percent increase or
decrease in linear dimension to the nearest 0.001 % of the gage
length based on the initial measurement made at the time of
removal from the molds, and
13.1.11 Any other pertinent information.