BASE TRANSCEIVER STATION

AirLink 8000
1/30/00
BASE TRANSCEIVER STATION
Release 1.00
2 - 8
1.3.2 Base Transceiver Station
The BTS consists of a standard front access 19” telephony equipment rack (31U high), populated with up
to four equipment subracks. The subracks provide all the functionality required to interface to the DSCO
and may include the electronics for 1 or 2 Radio Base Units (RBUs) which provide radio communication
to all CPE within a cell or sector. The RBUs are connected to external antennas that communicate with
the SUs. 
1.3.3 Base Transceiver Station - Mechanical
The antennas can be located up to 100 meters from the BTS using a 50 W coaxial cable. The antenna
location is chosen to optimize transmission characteristics to the served SUs (principally line of sight).
The RBU is fully redundant and all field replaceable units are hot-swappable. RBU accepts 48 or 60 VDC
power with 15% tolerance.
Base Transceiver Station - Mechanical


AirLink 8000
1/30/00
BASE TRANSCEIVER STATION
Release 1.00
2 - 9
1.3.4 Eagle Management Suite
The EMS is a personal computer based platform that is used to provide all the Operations,
Administration, Maintenance, and Provisioning (OAM&P) control for the system. The EMS is hosted on
a Windows NT
®
compatible PC platform and uses a Graphical User Interface (GUI) to facilitate operator
inputs and report system information. Functions managed by the EMS include initiation, control, and data
logging of all system wide tests, alarm reporting, operator entry of system parameters, and entry and
maintenance of subscriber information such as priority, ID, and phone number. The EMS also acts as the
administration terminal for system configuration and reporting.
1.3.5 Customer Premises Equipment
The Customer Premises Equipment consists of three separate hardware units — the Subscriber Unit (SU),
the Network Termination Unit (NTU) and the Uninterruptible Power Supply (UPS). All of the CPE units
are located at or near the end user’s location. A typical installation would find the SU located on an
exterior wall or rooftop to enable wireless communication with the RBU antenna, the NTU mounted at a
ground accessible exterior point on the customer building, and the UPS located within the building.