9- : coi Drum chuïp bao nhieâu baûn
Ñoàng hoà bay: menu 3-next-set
Senso: (kyõ thuaät) phaàøn töû nhaûy; caùi caûm bieán
Supply: söï cung caáp; ñöôïc cung caáp
FT 3113/3313/3413
ERROR CODE
E - CODE CONTENTS SP#
11 EXPOSURE LAMP ERROR 122
12 EXPOSURE LAMP ERROR 122
13 ZERO CROSS SIGNAL ERROR -
21 SCANNER H.P. ERROR 121
22 SCANNER H.P. ERROR 121
28 LENS H.P. ERROR 121
29 LENS H.P. ERROR 121
2A 4th/5th MIRROR H.P. ERROR 121
2B 4th/5th MIRROR H.P. ERROR 121
52 FUSING WAPM-UPERROR 124
53 FUSING OVERHEAT 124
55 FUSING THERMISTOR OPEN 124
70 USED TONER OVERFTOW -
96 DF TIMING PUSE ERROR 125
FT4415/4418/4421
E - CODE CONTENTS SP#
11 EXPOSURE LAMP ERROR 122
12 EXPOSURE LAMP ERROR 122
13 ZERO CROSS SIGNAL ERROR -
21 SCANNER H.P. ERROR 121
22 SCANNER H.P. ERROR 121
28 LENS H.P. ERROR 121
29 LENS H.P. ERROR 121
2A 4th/5th MIRROR H.P. ERROR 121
2B 4th/5th MIRROR H.P. ERROR 121
52 FUSING WAPM-UPERROR 124
53 FUSING OVERHEAT 124
55 FUSING THERMISTOR OPEN 124
70 TONER OVERFLOW SENSOR ON -
80 DUPLEX & COPIER MAIN BOARD COMMUNICTION ERROR 125
81 INTERFACE BOARD ERROR 125
82 JOGGER H.P. ERROR 125
83 JOGGER H.P. ERROR 125
FT 4420/4422
E - CODE CONTENTS SP#
11 EXPOSURE LAMP ERROR 122
12 EXPOSURE LAMP ERROR 122
13 ZERO CROSS SIGNAL ERROR -
21 SCANNER H.P. ERROR 121
22 SCANNER H.P. ERROR 121
28 LENS H.P. ERROR 121
29 LENS H.P. ERROR 121
2A 4th/5th MIRROR H.P. ERROR 121
2B 4th/5th MIRROR H.P. ERROR 121
52 FUSING WAPM-UPERROR 124
53 FUSING OVERHEAT 124
55 FUSING THERMISTOR OPEN 124
70 TONER OVERFLOW SENSOR ON -
80 DUPLEX & COPIER MAIN BOARD COMMUNICTION ERROR 125
82 JOGGER H.P. ERROR 125
83 JOGGER H.P. ERROR 125
FT 4490
SERVICE CODE
11 EXPOSURE LAMP MALFUNCTION
21 SCANNER H.P. SENSOR NOT ON
23 NO REGISTRATION START SIGANL
24 NO SCANNER HOME POSTTION SIGANL
28 LENS H.P. ERROR NOT ON
29 LENS H.P. ERROR NOT OFF
2A 2ND SCANNER HP. SENSOR NOT ON
2B 2ND SCANNER HP. SENSOR NOT OFF
2C SCANNER MOTOR TOO FAST
2D SCANNER MOTOR TOO SLOW
31 DRUM THERMISTOR
32 IMAGE DENSTY SENSOR
41 SRD CASSETTE TRAY LIFT MOTOR
53 FUSING THERMISTOR ABNORMAL
54 FUSING WAPM-UP FAILURE
55 FUSING OVERHEAT
56 FUSING TEMPERATURE LOW
61 PULSE GENERTOR ABNORMAL
91 OPTISC< = > MAIN COMMUNICATION FAILURE
93 ID SENSOR ABNORMAL
FT 4495
E11 EXPOSURE LAMP ERROR (L5/TS OPEN)
E12 EXPOSURE LAMP ERROR
E13 ZERO CROSS SIGAL ERROR
E21 IST SCANNER HOME POSTTION ERROR (S1 = LOW)
E22 IST SCANNER HOME POSTTION ERROR (S1 = HIGH)
E28 LENS HOME POSTTION ERROR (S2 = HIGH)
E29 LENS HOME POSTTION ERROR (S2 = LOW)
E2A 2ND SCANNER HOME POSTTION ERROR (S3 = HIGH)
E2B 2ND SCANNER HOME POSTTION ERROR (S3 = LOW)
E31 DRUM THERMISTOR FAILURE (TH1 = OPEN OR SHORT)
E52 FUSING WAPM-UP ERROR (L4 = OPEN)
E53 FUSING OVERHEAT (TH3 = SHORT)
E55 FUSING THERMISTOR OPEN (TH3 = OPEN)
E70 TONER OVERFLOW CONDTTION OCCURS EMPTY USED TONER COLLECTION BOTTLE SET SP83=1
E71 OIL END CONDTTION OCCURS FILL OIL BOTTLE TO MAX … SET SP84=1
U6 SUSING UNIT NOT SET
FT 4027/4527/5035/5535
U - CODE TABLE
U-code Condition Message on LCD (a156 only)
U2 Key counter not set Insert a key counter of enabling device/Eter a user code
U6 Fusing unit not set Open the font cover anh reset the fusing unit
U7 Duplex unit not set Insert the duplex unit
FT 5580/5590
SERVICE CALL CONDITIONS
CODE CONDITIONS
11 EXPOSURE LAMP MALFUNCTION
12 LAMP RELAY OPEN
21 SCANNER HOME POSITION NOT ON
22 SCANNER HOME POSITION NOT OFF
24 NO HOME POSITION SIGNAL
25 NORMAL ENCOEDE PULSE
28 LENS HOME POSITION NOT ON
29 LENS HOME POSITION NOT OFF
2A 4TH/5TH MIRROR HOME POSITION NOT ON
2B 4TH/5TH MIRROR HOME POSITION NOT FF
2D NO ENCODER OUTPUT
31 DRUM THERMISTOR BLOWN
52 THERMOFUSE BLOWN
53 THERMOFUSE BLOWN
54 REDY SIGNAL NOT ON
55 FUSING OVEHEAT
61 PULES GENERTOR MALFUNCTION
81 JOGGER HOME POSITION NOT ON
82 JOGGER HOME POSITION NOT OFF
91 TOTAL COUNTER MALFUNCTION
FT 5233/5433/5733
SEVICE CALL CONDITION
CODE # PROBLEM
11 EXPOSURE LAMP ERROR ( STAND BY)
12 EXPOSURE LAMP ERROR ( COPYING)
20 SCANNER MOTOR
21 SCANNER MOTOR (H.P.ERROR STAYS ON)
22 SCANNER MOTOR (H.P.ERROR STAYS OFF)
23 LEAR EDGE SIGNAL ERROR
24 SCANNER H.P. SIGNAL ERROR
28 LENS H.P ERROR (H.P.ERROR STAYS OFF)
29 LENS H.P ERROR (H.P.ERROR STAYS ON)
2A 3DR SCANNER H.P.ERROR (H.P.ERROR STAYS ON)
2B 3DR SCANNER H.P.ERROR (H.P.ERROR STAYS OFF)
41 UPPER TRAY LIFT MOTOR ERROR
42 LOWER TRAY LIFT MOTOR
43 TRAY LIFT MOTOR 1 (PAPER TRAY UNIT)
44 TRAY LIFT MOTOR 2 (PAPER TRAY UNIT)
45 TRAY LIFT MOTOR 3 (PAPER TRAY UNIT)
46 LCF LIFT MOTOR
53 FUSING THERMISTOR OPEN
54 FUSING WAPM-UP ERROR
55 FUSING OVERHEAT
61 MAINDRIVE MOTOR ERROR
62 TRANSPORT FAN MOTOR ERROR
63 EXHUST BLOWER MOTOR ERROR
64 FUSING EXHUST FAN MOTOR ERROR
72 TRANSFER CORONA CURENT ADJ ERROR
73 SEPARATION COROA CURENT ADJ ERROR
74 ID SENSOR ADJ ERROR
75 V SENSOR ADJ ERROR
76 ADS SENSOR ADJ ERROR
81 JOGGER H.P.ERROR (H.P.ERROR STAYS ON)
82 JOGGER H.P.ERROR (H.P.ERROR STAYS OFF)
91 TOTAL COUNTER ERROR
92 TOTAL COUNTER SHORT
93 INTERFAC SIGGNAL ERROR
94 EDITOR SIGNAL ERROR
95 AREA CODE DETECTION ERROR
DE VL INTTTAL DETECTION ERROR
SORTER STAPLER
H1 PROOFMOTOR ERROR
H2 TLMING SENSORH.P SENSOR OUTPUT ERROR
H3 JOGGER H.P SENSOR OUTPUT ERROR
H4 STAPLE UNIT POSTTION ERROR
H5 GRIP MOTOR ERROR
H6 STAPLE ERROR
H7 BIN SIDE PLATEDRIVE MOTOR ERROR
FW 810
CODE DISPLAY* FUNCTION
E1 SP 58 EXPOSURE LAMP ABNORMAL
E2 IMMEDITE FUSING THERMISTOR OPEN
E3 IMMEDITE HOT ROLLER THERMISTOR OPEN
E4 IMMEDITE HOT ROLLER THERMISTOR SHORT
E5 IMMEDITE PRESSURE ROLLER THERMISTOR OPEN
E6 IMMEDITE PRESSURE ROLLER THERMISTOR SHORT
E7 SP59 EXPOSURE LAMP THERMISTOR OPEN
E8 IMMEDITE EXPOSURE LAMP THERMISTOR SHORT
E9 IMMEDITE FUSING OVERHEAT
EA IMMEDITE READY FAILURE
EB SP60 ABNOMALDRIVE
EC IMMEDITE ABNOMAL TOTAL COUNTER
ED IMMEDITE ABNOMAL TONER DENSTTY SENSOR
EF SP 61 ABNOMAL ID SENSOR
2. SERVICE CALL CONDITION
When a service call condition occurs, the Call Service indicator and service call codes are displayed.
When a service call conditions E2, E3, E4, E5, E6,E7, E8, and E15 conditions occurs, for sajety reason they cannot be cleared by turning the main switch off and on. Accessing SP4 and changing the date from "1" to "0" must be done to clear these service call conditions.
2.1 SC CODE E1 : EXPOSURE LAMP ABNORMAL
- Definition-
The light sensor voltage is less than 0.4 volts for 10 seconds
Exposure lamp
Light sensor
FL regulator (CN 401- 1, -2,-3)
Main board (CN 102 - B10, -B11, -B12 and CN 105 - B27, -B28, -B28, -B29, -B30)
2.2 SC CODE E-2 :FUSING THERMOFUSE OPEN
- Definition-
The temperature detected by the hot roller thermistor does not reach 100oC within 40 minutes and 30 seconds after the main switch is tunred on.
Fusing thermofuse
Hot roller thermistor
AC drive board (CN203-2, T203)
Main board (CN106, -A4, -A5,and CN102-A20)
2.3 SC CODE E-3: HOT ROLLER THERMISTOR OPEN
- Definition-
The temperature detected by the hot roller thermistor does not reach 50oC within 3 minutes after the main switch is tunred on.
Hot roller thermistor
AC drive board (CN203-2, T203)
Fusing thermofuse
Main board (CN106, -A4, -A5,and CN102-A20)
2.4 SC CODE E-4: HOT ROLLER THERMISTER SHORT
- Definition-
The resistance of the the hot roller thermistor is less than 0.11 K§Ù
Hot roller thermistor
Main board (CN106, -A4, CN102-A20)
2.5 SC CODE E-5: PRESSURE HOT ROLLER THERMISTOR OPEN
- Definition-
The resistance of the the pressure roller thermistor is more than 0.53 K§Ù
Pressure roller thermistor
Main board (CN106, -A6, -A7)
2.6 SC CODE E-6: PRESSURE HOT ROLLER THERMISTOR SHORT
- Definition-
The resistance of the the pressure roller thermistor is more than 0.55 K§Ù
Pressure roller thermistor
Main board (CN106, -A6, -A7)
2.7 SC CODE E-7 FUSING OVERHEAT
- Definition-
The temperature detected by the hot roller thermistor becomes higher than 2200C
Hot roller thermistor
Fusing thermofuse
AC drive board (CN203-2, T203)
Main board (CN102 -A20)
2.8 SC CODE E-8:FUSING WRAM - UP ERROR
- Definition-
The temperature detected by the hot roller thermistor does not reach the target ready temperature within 12 minutes after main switch is turned on.
Hot roller thermistor
Fusing lamp
Fusing thermofuse
AC drive board (CN203-2, T203)
Main board (CN102 -A20)
AC harness
2.9 SC CODE E-9 :TONER DENSITY SENSOR BNORMAL
- Definition-
The toner density sensor voltage is less than 0.5 volts or more than 4.5 volts.
NOTE : 4.5 volts condition is not detected unitl 251 copiec since initializingdeveloper
Toner density sensor
Flow of the developer at the density sensor area
Main board (CN 105-B15, -B16, -B17, -B18)
2.10 SC CODE E-10: MAIN MOTOR BNORMAL
- Definition-
The main board does not receive a signal from the main motor for 2 senconds white the main motor is on
Main motor
Mechanical interfrence of the min motor drive
Main board (CN102-A8, -A9)
2.11 SC CODE E-11: DEVELOPMENT MOTOR ABNORMAL
- Definition-
1. Development motor does not output LOCK signal within 2 sensond after the motor is enefgized
2. LOCK signal is not in LOW level before the development motor is energized
Development motor
Mechaincal interference of the development motor
Main board ( CN 102-A5, -A7)
2.12 SC CODE E-12: CHARGE CORONA CLEANER MOTOR ABNORMAL
- Definition-
1. The over current of charge corona wire drive motor is not detected continually for 1.5 senconds within 3 minutes after main switch is tunred on
2. The over current of charge corona wire drive motor is not detected twice within 3 minutes after the charge corona motor is energized
Charge cleaner motor
Mechanical interference of the charge cleaner motor
2.13 SC CODE E-13: TOTAL COUNTER ABNORMAL
- Definition-
Total counter and its connection
Total counter and its connection
2.14 SC CODE E-14: ZERO CROSS SIGNAL DETECTION BNORMAL
- Definition-
The zero cross signal is not detected within 0.5 sensond after the main switch is turmed on
Main board ACDrive board
2.15 SC CODE E-15: MAIN SWITCH ABNORMAL (U.S.A version only)
- Definition-
The main switch does not turn off switch 0.45 second after sending reset signal
Main Switch
Main board
2.16 SC CODE E-16: TONER DENSITY SENSOR ADFUSTMENT ERROE
- Definition-
The toner density sensor voltage cannot be adjusted to its standard value (4.1--± 0.1 volts) during the new developer initialization
NOTE: If clearing the SC condition, the previous data of SP#-61 is still used unitl its next inialization
Toner density sensor
Developer
Floe of the developer at the toner density sensor area
Main board (CN 104-A10,-A11, -B20, -B21)
2.17 SC CODE E-17: ADS AUTO DJUSTMENT FAILURE
- Definition-
The ADS sensor voltage cannot adjusted to its stndard value (3.9± 0.2v) during the ADS auto adjusment (SP# -56)
ADS pattern
ADS sensor
2.18 SC CODE E-18: ORIGINA REGISTRATION AUTO ADJUSTMENT FAILURE
- Definition-
The origina registration sensor voltage cannot be adjustment to its standard value (3±0.2 v) during the origina registration auto adjustment (SP#-50)
Original registration sensor
XEROX V250
When a service call condition occurs the call sevice indicator and service call codes are displayed
When a service call condition E2,E3,E4,E5,E6,E7 and E8 conditioons occur, for sfety reason they cannot be cleared by turning the main switch off and on. Accsessing SP38and changing the dte from "1" to "0" must de done to clear these service call conditions
2.1 SC CODE E-1: EXPOSURE LAMP ABNORMAL
- Definition-
The light sensor voltage is less than 0.4 volts for 10 second
Exposure lamp
Light sensor (CN402-1,2,4, and5,CN401-1,2,-4)
Main board (cn106-A3, andCN104-B1,-B2 ,-A29,-A30)
2.2 SC CODE E-2: FUSING THERMOFUSE OPEN
- Definition-
The temperature detected by the hot roller thermistor boes not reach 100oC within 4 minutes and 30 seconds after the main switch is turned on
Fusing thermofuse
Hot roller thermistor
AC drive board (T202-2,RA201-T4)
Main board (CN106-A2,A4,B12,B14,B15)
2.3 SC CODE E-3: HOT ROLLER THERMISTOR OPEN
- Definition-
The temperature detected by the hot roller thermistor boes not reach 50oC within 3 minutes after the main switch is turned on
Hot roller thermistor
AC drive board (T202-2,RA201-T4)
Fusing thermofuse
Main board (CN106-A2,-A5,-B11,-B14,-B15)
2.4 SC CODE E-4: HOT ROLLER THERMISTOR SHORT
- Definition-
The resistance of the hot roller thermistor is less than 0.11 k §Ù
Hot roller thermistor
Main board (CN106-A2,-A5,-B11,-B14,-B15)
2.5 SC CODE E-5: PRESSURE ROLLER THESMISTOR OPEN
- Definition-
The resistance of the hot roller thermistor is more than 0.53 k §Ù
Pressure roller thermistor
Main board (CN106-A2,-A4,-B12,-B14,-B15)
2.6 SC CODE E-6: PRESSURE ROLLER THESMISTOR SHORT
- Definition-
The resistance of the hot roller thermistor is less than 0.55 k §Ù
Pressure roller thesmistor
Main board (CN106-A2,-A5,-B11,-B14,-B15)
2.7 SC CODE E-7: FUSING OVERHEAT
- Definition-
Hot roller thermistor
Fusing thermistor
AC drive board (T202-2, RA201-T4)
Main board (CN106-A2,-B14,-B15)
2.8 SC CODE E-8: FUSING WARM - UP ERROR
- Definition-
The temperature detected by the hot roller thermistor does not reach the target realy temperture within 12 minutes after main wsitch is turned on
Hot roller thermistor
Fusing lamp
Fusing thermofuse
Ac drive board (T202-2,RA201-T4)
Main board (CN106-A2,-A5,-B11,-B14,-B15)
Acharness
2.9 SC CODE E-9: TONER DENSITY SENSOR ABNORMAL
-Definition-
The toner density sensor voltage is less than 0.5 volts or more than 4.5 volts
NOTE: This condition is not detected until 251 copies since initializing
Toner density sensor
Flow of the developer at the toner density sensor area
Main board (CN104-A10,-A11,-B20,-B21)
2.10 SC CODE E-10: MAIN MOTOR ABNORML
-Definition-
The main board does not receive a signal from the main motor for 2 seconds while the main motor is on
Main motor
Mechanical interfence of the main motor drive
Main board (CN 106-A12, -A13)
2.11 SC CODE E-11: TONER DENSITY SESOE ADJUSTMENT ERROR
-Definition-
The toner density sensor voltage cannot be adjusted to its standard value (4.1 ±0.1 volts) during the new developer initiazation
NOTE: If clearing the SC condition, the previous data of SP#-30 is still usde until its next initialization
Toner density sensor
Developer
Flow of the developer at the density sensor aera
Main board (CN104-A10, -A11,-B20, -B21)