TECHNICAL
N12
Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328
ANSI/TIA
-568-
C.2
Table 1: Categories of Transmission Performance
and Field Test Parameters
Insertion
Wire
Delay
Return
Category
Loss
NEXT
Length
Map
Skew
ELFEXT
Loss
PSACR PSELFEXT
PSNEXT ANEXT
Cat 3 (16 MHz)
Cat 5e (100 MHz)
Cat 6 (250 MHz)
Cat 6A (500 MHz)
NEXT Loss
Frequency
Cat 5e
Cat 6
Cat 6A
(MHz)
(dB)
(dB)
(dB)
1.0
60.0 65.0 65.0
4.0
54.8 64.1 64.1
8.0
50.0 59.4 59.4
10.0
48.5 57.8 57.8
16.0
45.2 54.6 54.6
20.0
43.7 53.1 53.1
25.0
42.1 51.5 51.5
31.25
40.5 50.0 50.0
62.5
35.7 45.1 45.1
100.0
32.3 41.8 41.8
200.0
-
36.9
36.9
250.0
-
35.3
35.3
300.0
-
-
34.0
400.0
-
-
29.9
500.0
-
-
26.7
Return Loss
Frequency
Cat 5e
Cat 6
Cat 6A
(MHz)
(dB)
(dB)
(dB)
1.0
19.0
19.1
19.1
4.0
19.0
21.0
21.0
8.0
19.0
21.0
21.0
10.0
19.0
21.0
21.0
16.0
19.0
20.0
20.0
20.0
19.0
19.5
19.5
25.0
18.0
19.0
19.0
31.25
17.1
18.5
18.5
62.5
14.1
16.0
16.0
100.0
12.0
14.0
14.0
200.0
-
11.0
11.0
250.0
-
10.0
10.0
300.0
-
-
9.2
400.0
-
-
8.0
500.0
-
-
8.0
Insertion Loss
Frequency
Cat 5e
Cat 6
Cat 6A
(MHz)
(dB) (dB) (dB)
1.0
2.1
1.9
1.9
4.0
3.9
3.5
3.5
8.0
5.5
5.0
5.0
10.0
6.2
5.5
5.5
16.0
7.9
7.0
7.0
20.0
8.9
7.9
7.8
25.0
10.0
8.9
8.8
31.25
11.2
10.0
9.8
62.5
16.2
14.4
14.1
100.0
21.0
18.6
18.0
200.0
-
27.4
26.1
250.0
-
31.1
29.5
300.0
-
-
32.7
400.0
-
-
38.5
500.0
-
-
43.8
Permanent Link Performance
Insertion Loss
Frequency
Cat 5e
Cat 6
Cat 6A
(MHz)
(dB)
(dB)
(dB)
1.0
2.2
2.1
2.3
4.0
4.5
4.0
4.2
8.0
6.3
5.7
5.8
10.0
7.1
6.3
6.5
16.0
9.1
8.0
8.2
20.0
10.2
9.0
9.2
25.0
11.4
10.1
10.2
31.25
12.9
11.4
11.5
62.5
18.6
16.5
16.4
100.0
24.0
21.3
20.9
200.0
-
31.5
30.1
250.0
-
35.9
33.9
300.0
-
-
37.4
400.0
-
-
43.7
500.0
-
-
49.3
Return Loss
Frequency
Cat 5e
Cat 6
Cat 6A
(MHz)
(dB)
(dB)
(dB)
1.0
17.0
19.0
19.0
4.0
17.0
19.0
19.0
8.0
17.0
19.0
19.0
10.0
17.0
19.0
19.0
16.0
17.0
18.0
18.0
20.0
17.0
17.5
17.5
25.0
16.0
17.0
17.0
31.25
15.1
16.5
16.5
62.5
12.1
14.0
14.0
100.0
10.0
12.0
12.0
200.0
-
9.0
9.0
250.0
-
8.0
8.0
300.0
-
-
7.2
400.0
-
-
6.0
500.0
-
-
6.0
NEXT Loss
Frequency
Cat 5e
Cat 6
Cat 6A
(MHz)
(dB)
(dB)
(dB)
1.0
60.0
65.0
65.0
4.0
53.5
63.0
63.0
8.0
48.6
58.2
58.2
10.0
47.0
56.6
56.6
16.0
43.6
53.2
53.2
20.0
42.0
51.6
51.6
25.0
40.3
50.0
50.0
31.25
38.7
48.4
48.4
62.5
33.6
43.4
43.4
100.0
30.1
39.9
39.9
200.0
-
34.8
34.8
250.0
-
33.1
33.1
300.0
-
-
31.7
400.0
-
-
28.7
500.0
-
-
26.1
Channel
Performance
NEXT Loss - Category 6
Frequency
Cord Limit (dB)
(MHz) 2m 5m 10m
1.0 65.0 65.0 65.0
4.0 65.0 65.0 65.0
8.0 65.0 65.0 64.8
10.0 65.0 64.5 62.9
16.0 62.0 60.5 59.0
20.0 60.1 58.6 57.2
25.0 58.1 56.8 55.4
31.25 56.2 54.9 53.6
62.5 50.4 49.2 48.1
100.0
46.4
45.3
44.4
125
44.5
43.5
42.7
150
43.0
42.1
41.4
175
41.8
40.9
40.2
200
40.6
39.8
39.3
225
39.7
38.9
38.4
250
38.8
38.1
37.6
Return Loss
Frequency
Cat 5e
Cat 6
Cat 6A
(MHz)
(dB)
(dB)
(dB)
1.0
25.0 25.0 20.0
4.0
25.0 25.0 23.0
8.0
25.0 25.0 24.5
10.0
25.0 25.0 25.0
16.0
25.0 25.0 25.0
20.0
24.0 25.0 25.0
31.25
23.1 23.1 23.3
62.5
20.1 20.1 20.7
100.0
18.0 18.0 19.0
200.0
-
15.0
16.4
250.0
-
14.0
15.6
300.0
-
-
14.9
400.0
-
-
13.8
500.0
-
-
13.0
Patch Cord Performance
ANSI/TIA-568-C.2: Balanced Twisted Pair Cabling and Components
The tables below incorporate enhanced performance requirements for UTP cables and connecting hardware: Category 3, 5e, 6, and 6A.
All Hubbell products exceed these minimum requirements.
ANSI/TIA-568-C.2: Balanced Twisted Pair Cabling Components
This standard specifies electrical performance requirements for installed UTP cable and connecting hardware for each recognized category. Augmented
Category 6 with extended frequency and additional parameters (ANEXT) is included. Performance categories, bandwidth, and field test parameters are
listed in the table below. Refer to the glossary for explanation of test parameters.
NEXT Loss - Category 6A
Frequency
Cord Limit (dB)
(MHz)
1m
2m
5m 10m
1.0 65.0 65.0 65.0 65.0
4.0 65.0 65.0 65.0 65.0
8.0 65.0 65.0 65.0 64.8
10.0
65.0
65.0
64.5 62.9
16.0
62.6
62.0
60.5 59.1
20.0
60.7
60.1
58.6 57.2
25.0
58.8
58.2
56.8 55.4
31.25 56.9
56.3
54.9 53.6
62.5
51.0
50.4
49.2 48.1
100.0
47.0
46.4
45.4
44.5
200
41.1
40.7
39.9
39.3
250
39.3
38.9
38.1
37.7
300
36.4
36.2
35.9
35.8
400
31.8
31.9
32.1
32.5
500
28.2
28.4
29.0
29.8
TECHNICAL
Call 1-800-626-0005
www.hubbell-premise.com
N13
ANSI/TIA
-568-
C.2
Permanent Link
The permanent link test configuration
includes a length of
horizontal cable and one connector attached to each end (see
diagram). One optional consolidation point connection is also
permitted. The permanent link runs from the cross-connect panel
in the TR to the work station outlet. The permanent link overall
length must not exceed 90m (295 ft.).
Field T
est
Instrument
Field T
est
Instrument
Begin
Link
End
Link
90m (295’)
Horizontal Cable
Hand Held
Tester Cord
Hand Held
Tester Cord
Telco Outlet
Horizontal
Cross
Connect or
Interconnect
Channel
The channel test configuration includes a length of horizontal
cable up to 90 meters, a work area cord, and two patch cord
cross connections (see diagram). One optional consolidation
point connection is also permitted in the channel.
The channel
overall length must not exceed 100m (328 ft.).
Hubbell Approved Field Testers for UTP and Optical Fiber Cabling
The Hubbell MISSION CRITICAL
®
warranty program recognizes the field testers and associated test adapters below. These testers
function in a bidirectional mode, with automatic data acquisition and storage.
All MISSION CRITICAL
®
test parameters are measured
and recorded with these testers, for copper or fiber cabling.
Begin
Channel
End
Channel
90m (295’)
Horizontal
Cable
Telco Outlet
Work Area
Patch Cord
TR
Equipment
Patch Cord
Horizontal Cross
Connect
Field T
est
Instrument
Field T
est
Instrument
Permanent
110
Block
110 Block
Cat 6A
Field Tester Model
Link Adapter
Channel Adapter
T568A
Wiring
T568B Wiring
AXT Test Kit
Fluke DTX
Series
Cat 5e/
DTX-PLA001
DTX-CHA001
DTX-PLA001
DTX-PLA001
PLA002
1800 and 1200
Cat 6
w/DSP-PM06
w/DSP-PM13A
w/DSP-PM13B
Cat
6A
DTX-PLA0025
DTXCHAOO1AS
N/A
N/A
DTX-10GKIT
Fluke DSP Series
Cat 5e/
DSP-LIA101S
DSP-LIA012S
DSP-PM13A
DSP-PM13B
4000, 4100
Cat 6A
w/DSP-PM06
and
4300
Cat
6A
N/A N/A N/A
N/A N/A
Fluke OMNIScanner
Cat 5e/
OMNI-LIA101S
8262-42
OMNI-LIA101S
OMNI-LIA101S
and OMNIScanner 2
Cat 6
w/DSP-PM06
w/DSP-PM13A
w/DSP-PM13B
Cat
6A
N/A N/A N/A
N/A N/A
Agilent Wirescope 350 Cat 5e/
N2604A-101
N2604A-100
N2604A-065
N2604A-066
and FrameScope 350 Cat 6
Wirescope Pro
Cat 6A
N2644A-101
N2644A-100
N/A
N/A
N2648A-100
Ideal Lantek 6 and
Cat 5e/
HPW PCX6Patch Cord 0012-00-0629
1019-00-1112 (Kit) 1019-00-1112 (Kit)
Lantek 7
Cat 6
Lantek 6A-7G
Cat 6A
HPW PS6 Series
Supplied in unit
N/A
N/A
LANTEK
atch
Cord
10GBKIT
Chia sẻ với bạn bè của bạn: