ANSI-TIA Standards
8718 source
ANSI/TIA-568-C.1
Telecommunications Room (TR)
Equipment Room (ER)
Entrance Facility (EF)


TECHNICAL
N12
Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328
ANSI/TIA
-568-
C.2
Table 1: Categories of Transmission Performance and Field Test Parameters
Insertion 
Wire 
Delay 
Return
Category 
Loss 
NEXT 
Length 
Map 
Skew 
ELFEXT 
Loss 
PSACR PSELFEXT 
PSNEXT ANEXT
Cat 3 (16 MHz) 




Cat 5e (100 MHz) 










Cat 6 (250 MHz) 










Cat 6A (500 MHz) 











NEXT Loss
Frequency 
Cat 5e 
Cat 6 
Cat 6A
(MHz) 
(dB) 
(dB) 
(dB)
1.0 
60.0 65.0 65.0
4.0 
54.8 64.1 64.1
8.0 
50.0 59.4 59.4
10.0 
48.5 57.8 57.8
16.0 
45.2 54.6 54.6
20.0 
43.7 53.1 53.1
25.0 
42.1 51.5 51.5
31.25 
40.5 50.0 50.0
62.5 
35.7 45.1 45.1
100.0 
32.3 41.8 41.8
200.0 

36.9 
36.9
250.0 

35.3 
35.3
300.0 


34.0
400.0 


29.9
500.0 


26.7
Return Loss
Frequency 
Cat 5e 
Cat 6 
Cat 6A
(MHz) 
(dB) 
(dB) 
(dB)
1.0 
19.0 
19.1 
19.1
4.0 
19.0 
21.0 
21.0
8.0 
19.0 
21.0 
21.0
10.0 
19.0 
21.0 
21.0
16.0 
19.0 
20.0 
20.0
20.0 
19.0 
19.5 
19.5
25.0 
18.0 
19.0 
19.0
31.25 
17.1 
18.5 
18.5
62.5 
14.1 
16.0 
16.0
100.0 
12.0 
14.0 
14.0
200.0 

11.0 
11.0
250.0 

10.0 
10.0
300.0 


9.2
400.0 


8.0
500.0 


8.0
Insertion Loss
Frequency 
Cat 5e 
Cat 6 
Cat 6A
(MHz) 
(dB) (dB) (dB)
1.0 
2.1 
1.9 
1.9
4.0 
3.9 
3.5 
3.5
8.0 
5.5 
5.0 
5.0
10.0 
6.2 
5.5 
5.5
16.0 
7.9 
7.0 
7.0
20.0 
8.9 
7.9 
7.8
25.0 
10.0 
8.9 
8.8
31.25 
11.2 
10.0 
9.8
62.5 
16.2 
14.4 
14.1
100.0 
21.0 
18.6 
18.0
200.0 

27.4 
26.1
250.0 

31.1 
29.5
300.0 


32.7
400.0 


38.5
500.0 


43.8
 
Permanent Link Performance
Insertion Loss 
Frequency 
Cat 5e 
Cat 6 
Cat 6A
(MHz) 
(dB) 
(dB) 
(dB)
1.0 
2.2 
2.1 
2.3
4.0 
4.5 
4.0 
4.2
8.0 
6.3 
5.7 
5.8
10.0 
7.1 
6.3 
6.5
16.0 
9.1 
8.0 
8.2
20.0 
10.2 
9.0 
9.2
25.0 
11.4 
10.1 
10.2
31.25 
12.9 
11.4 
11.5
62.5 
18.6 
16.5 
16.4
100.0 
24.0 
21.3 
20.9
200.0 

31.5 
30.1
250.0 

35.9 
33.9
300.0 


37.4
400.0 


43.7
500.0 


49.3
Return Loss
Frequency 
Cat 5e 
Cat 6 
Cat 6A
(MHz) 
(dB) 
(dB) 
(dB)
1.0 
17.0 
19.0 
19.0
4.0 
17.0 
19.0 
19.0
8.0 
17.0 
19.0 
19.0
10.0 
17.0 
19.0 
19.0
16.0 
17.0 
18.0 
18.0
20.0 
17.0 
17.5 
17.5
25.0 
16.0 
17.0 
17.0
31.25 
15.1 
16.5 
16.5
62.5 
12.1 
14.0 
14.0
100.0 
10.0 
12.0 
12.0
200.0 

9.0 
9.0
250.0 

8.0 
8.0
300.0 


7.2
400.0 


6.0
500.0 


6.0
NEXT Loss
Frequency 
Cat 5e 
Cat 6 
Cat 6A
(MHz) 
(dB) 
(dB) 
(dB)
1.0 
60.0 
65.0 
65.0
4.0 
53.5 
63.0 
63.0
8.0 
48.6 
58.2 
58.2
10.0 
47.0 
56.6 
56.6
16.0 
43.6 
53.2 
53.2
20.0 
42.0 
51.6 
51.6
25.0 
40.3 
50.0 
50.0
31.25 
38.7 
48.4 
48.4
62.5 
33.6 
43.4 
43.4
100.0 
30.1 
39.9 
39.9
200.0 

34.8 
34.8
250.0 

33.1 
33.1
300.0 


31.7
400.0 


28.7
500.0 


26.1
Channel
 Performance
NEXT Loss - Category 6
Frequency 
Cord Limit (dB)
(MHz) 2m 5m 10m 
1.0 65.0 65.0 65.0
4.0 65.0 65.0 65.0
8.0 65.0 65.0 64.8
10.0 65.0 64.5 62.9
16.0 62.0 60.5 59.0
20.0 60.1 58.6 57.2
25.0 58.1 56.8 55.4
31.25 56.2 54.9 53.6
62.5 50.4 49.2 48.1
100.0 
46.4 
45.3 
44.4
125 
44.5 
43.5 
42.7
150 
43.0 
42.1 
41.4
175 
41.8 
40.9 
40.2
200 
40.6 
39.8 
39.3
225 
39.7 
38.9 
38.4
250 
38.8 
38.1 
37.6
Return Loss
Frequency 
Cat 5e 
Cat 6 
Cat 6A
(MHz) 
(dB) 
(dB) 
(dB)
1.0 
25.0 25.0 20.0
4.0 
25.0 25.0 23.0
8.0 
25.0 25.0 24.5
10.0 
25.0 25.0 25.0
16.0 
25.0 25.0 25.0
20.0 
24.0 25.0 25.0
31.25 
23.1 23.1 23.3
62.5 
20.1 20.1 20.7
100.0 
18.0 18.0 19.0
200.0 

15.0 
16.4
250.0 

14.0 
15.6
300.0 


14.9
400.0 


13.8
500.0 


13.0
Patch Cord Performance
ANSI/TIA-568-C.2: Balanced Twisted Pair Cabling and Components
The tables below incorporate enhanced performance requirements for UTP cables and connecting hardware: Category 3, 5e, 6, and 6A.
All Hubbell products exceed these minimum requirements.
ANSI/TIA-568-C.2: Balanced Twisted Pair Cabling Components
This standard specifies electrical performance requirements for installed UTP cable and connecting hardware for each recognized category. Augmented 
Category 6 with extended frequency and additional parameters (ANEXT) is included. Performance categories, bandwidth, and field test parameters are 
listed in the table below. Refer to the glossary for explanation of test parameters.
NEXT Loss - Category 6A
Frequency 
Cord Limit (dB)
(MHz) 
1m 
2m 
5m 10m 
1.0 65.0 65.0 65.0 65.0
4.0 65.0 65.0 65.0 65.0
8.0 65.0 65.0 65.0 64.8
10.0 
65.0 
65.0 
64.5 62.9
16.0 
62.6 
62.0 
60.5 59.1
20.0 
60.7 
60.1 
58.6 57.2
25.0 
58.8 
58.2 
56.8 55.4
31.25 56.9 
56.3 
54.9 53.6
62.5 
51.0 
50.4 
49.2 48.1
100.0 
47.0 
46.4 
45.4 
44.5
200 
41.1 
40.7 
39.9 
39.3
250 
39.3 
38.9 
38.1 
37.7
300 
36.4 
36.2 
35.9 
35.8
400 
31.8 
31.9 
32.1 
32.5
500 
28.2 
28.4 
29.0 
29.8


TECHNICAL
Call 1-800-626-0005
www.hubbell-premise.com
N13
ANSI/TIA
-568-
C.2
 Permanent Link
The permanent link test configuration includes a length of 
horizontal cable and one connector attached to each end (see 
diagram). One optional consolidation point connection is also 
permitted. The permanent link runs from the cross-connect panel 
in the TR to the work station outlet. The permanent link overall 
length must not exceed 90m (295 ft.).
Field T
est
Instrument
Field T
est
Instrument
Begin 
Link
End 
Link
90m (295’) 
Horizontal Cable
Hand Held 
Tester Cord
Hand Held 
Tester Cord
Telco Outlet
Horizontal Cross 
Connect or 
Interconnect
 Channel
The channel test configuration includes a length of horizontal 
cable up to 90 meters, a work area cord, and two patch cord 
cross connections (see diagram). One optional consolidation 
point connection is also permitted in the channel. The channel 
overall length must not exceed 100m (328 ft.).
Hubbell Approved Field Testers for UTP and Optical Fiber Cabling
The Hubbell MISSION CRITICAL
®
warranty program recognizes the field testers and associated test adapters below. These testers 
function in a bidirectional mode, with automatic data acquisition and storage. All MISSION CRITICAL
®
test parameters are measured 
and recorded with these testers, for copper or fiber cabling.
Begin 
Channel
End 
Channel
90m (295’) 
Horizontal 
Cable
Telco Outlet
Work Area
Patch Cord
TR 
Equipment
Patch Cord
Horizontal Cross 
Connect
Field T
est
Instrument
Field T
est
Instrument
Permanent
110 Block 
110 Block 
Cat 6A
Field Tester Model 
Link Adapter 
Channel Adapter 
T568A Wiring 
T568B Wiring 
AXT Test Kit
Fluke DTX Series 
Cat 5e/ 
DTX-PLA001 
DTX-CHA001 
DTX-PLA001 
DTX-PLA001 
PLA002 
1800 and 1200 
Cat 6 
w/DSP-PM06 
w/DSP-PM13A 
w/DSP-PM13B
Cat 
6A 
DTX-PLA0025 
DTXCHAOO1AS 
N/A 
N/A 
DTX-10GKIT
Fluke DSP Series 
Cat 5e/ 
DSP-LIA101S 
DSP-LIA012S 
DSP-PM13A 
DSP-PM13B
4000, 4100 
Cat 6A 
w/DSP-PM06
and 
4300
Cat 
6A 
N/A N/A N/A 
N/A N/A
Fluke OMNIScanner
Cat 5e/ 
OMNI-LIA101S 
8262-42 
OMNI-LIA101S 
OMNI-LIA101S
and OMNIScanner 2 
Cat 6 
w/DSP-PM06 
w/DSP-PM13A 
w/DSP-PM13B
Cat 
6A 
N/A N/A N/A 
N/A N/A
Agilent Wirescope 350 Cat 5e/ 
N2604A-101 
N2604A-100 
N2604A-065 
N2604A-066
and FrameScope 350 Cat 6
Wirescope Pro 
Cat 6A 
N2644A-101 
N2644A-100 
N/A 
N/A 
N2648A-100
Ideal Lantek 6 and 
Cat 5e/ 
HPW PCX6Patch Cord 0012-00-0629 
1019-00-1112 (Kit) 1019-00-1112 (Kit) 
Lantek 7 
Cat 6
Lantek 6A-7G 
Cat 6A 
HPW PS6 Series 
Supplied in unit 
N/A 
N/A 
LANTEK
atch 
Cord 
10GBKIT

tải về 0.82 Mb.

Chia sẻ với bạn bè của bạn:
1   ...   5   6   7   8   9   10   11   12   ...   30




Cơ sở dữ liệu được bảo vệ bởi bản quyền ©hocday.com 2024
được sử dụng cho việc quản lý

    Quê hương