manufacturers executable code (MEC)
The manufacturers executable code (MEC) file contains the complete software package
for one NE.
MDI
See
“miscellaneous discrete input” (p. GL-5)
.
MDO
See
“miscellaneous discrete output” (p. GL-5)
.
MEC
See
“manufacturers executable code” (p. GL-5)
.
MIB
See
“management information base” (p. GL-5)
.
miscellaneous discrete input (MDI)
A miscellaneous discrete input (MDI) is an input to a network element for external
equipment. MDIs can be monitored by the management system. An MDI can be
connected to monitor a temperature sensor or a door contact, for example.
miscellaneous discrete output (MDO)
A miscellaneous discrete output (MDO) is an output from a network element used to
drive external equipment. MDOs can be activated or deactivated by the management
system. An MDO can be connected to control a fan or a generator, for example.
MSP
See
“multiplex section protection” (p. GL-5)
.
multiplex section protection (MSP)
Multiplex section protection (MSP) is used to protect the traffic in a point-to-point
connection against transmission failures (MS-AIS, LOF, LOS, MS-DEG) and port
equipment failures. A requirement for this kind of protection is that the transmission
lines are doubled (one working line, one protection line).
A trail continues to use the working route until a fault condition occurs or an external
switch request is issued to switch to the protection route.