Traffic Signs Manual Chapter 4 Warning Signs


above road Height of gauge (diagram 781) and height to be shown



tải về 2.25 Mb.
Chế độ xem pdf
trang135/156
Chuyển đổi dữ liệu10.04.2022
Kích2.25 Mb.
#51583
1   ...   131   132   133   134   135   136   137   138   ...   156
traffic-signs-manual-chapter-4

above road
Height of gauge (diagram 781) and height to be shown 
on supplementary plate for different overhead line 
voltages
Signs to be used
25000 volts
Less than 25000 volts
Imperial
Metric
Imperial
Metric
Imperial
Metric
18′-9″
5.71 m
16′-9″
5.1 m
17′-3″
5.2 m
Diagram 779 with 
Figure 20-12
 and 
Figure 20-13
18′-6″
5.64 m
16′-6″
5.0 m
17′-0″
5.1 m
18′-3″
5.56 m


16′-9″
5.1 m
18′-0″
5.49 m


16′-6″
5.0 m
18′-3″
5.56 m
16′-6″
5.0 m


Load gauge 
(diagram 781) and 
diagram 779 with 
Figure 20-14
18′-0″
5.49 m
16′-3″
4.9 m


17′-9″
5.41 m
16′-0″
4.8 m
16′-6″
5.0 m
17′-6″
5.33 m
15′-9″
4.8 m
16′-3″
4.9 m
17′-3″
5.26 m
15′-6″
4.7 m
16′-0″
4.8 m
17′-0″
5.18 m
15′-3″
4.6 m
15′-9″
4.8 m
16′-9″
5.10 m
15′-0″
4.5 m
15′-6″
4.7 m
16′-6″
5.03 m
14′-9″
4.5 m
15′-3″
4.6 m
Load gauge
20.2.4.  The load gauge shown in diagram 781 (see 
Figure 20-14
) gives an audible warning 
when the safe height beneath an overhead power cable is exceeded. The number of the bells 
may be varied. The bells may be of any colour provided each bell is of the same colour. It 
should always be used where the safe height is less than 16’‑6” (5.03 m); see also 
20.3.2

A safe height less than 16’‑6” is likely to be encountered only at private crossings. At such 
locations the gauge should be effective as speeds are low and users are familiar with the layout. 
The gauge is for use with power cables and not at low bridges over public highways, where 
speeds are likely to be higher and drivers less able to respond to the sound of the bells in time
or even to hear them at all from inside closed cabs.
20.2.5.  The load gauge must be mounted on two posts coloured black and white in alternate 
horizontal bands, each band being not less than 250 mm nor more than 335 mm deep. 


80 
LEVEL CROSSINGS
Diagram 779 (see 
Figure 20-11
) with the supplementary plate shown in 
Figure 20-14
 should be 
used when a load gauge is installed.
BELLS
Figure 20-15 Diagram 781 (S2‑6‑5) Load gauge giving audible warning to drivers 
where vehicles exceed safe height under electrified overhead cables

tải về 2.25 Mb.

Chia sẻ với bạn bè của bạn:
1   ...   131   132   133   134   135   136   137   138   ...   156




Cơ sở dữ liệu được bảo vệ bởi bản quyền ©hocday.com 2024
được sử dụng cho việc quản lý

    Quê hương