PVSYST V6.88
|
|
19/05/22
|
Page 1/5
|
Grid-Connected System: Simulation parameters
Project : BLUESCOPE
Geographical Site KCN Phu My I Country Vietnam Situation Latitude 10.58° N Longitude 107.05° E
Time defined as Legal Time Time zone UT+7 Altitude 8 m Albedo 0.20
Meteo data: KCN Phu My I Meteonorm 7.2 (1991-2010), Sat=100% - Synthetic
|
SimPulation vaVriant : sBLUESyCOPE 14sMWP MtÁI ĐÔNGT_TÂY RIAL
Simulation date 19/05/22 09h25
|
Simulation parameters System type No 3D scene defined, no shadings
2 orientations tilts/azimuths 10°/-90° and 10°/90°
Models used Transposition Perez Diffuse Perez, Meteonorm
Horizon Free Horizon
Near Shadings No Shadings
User's needs : Unlimited load (grid)
|
PV PArrays ChaVracteristicss(2 kindys of arrasy definedt) TRIAL
PV module Si-mono Model LR4-72 HPH 435 M
Original PVsyst database Manufacturer Longi Solar
Sub-array "Sub-array #1" Orientation #1 Tilt/Azimuth 10°/-90° Number of PV modules In series 18 modules In parallel 894 strings Total number of PV modules Nb. modules 16092 Unit Nom. Power 435 Wp
Array global power Nominal (STC) 7000 kWp At operating cond. 6354 kWp (50°C) Array operating characteristics (50°C) U mpp 659 V I mpp 9635 A
Sub-array "Sub-array #2" Orientation #2 Tilt/Azimuth 10°/90° Number of PV modules In series 18 modules In parallel 894 strings Total number of PV modules Nb. modules 16092 Unit Nom. Power 435 Wp
Array global power Nominal (STC) 7000 kWp At operating cond. 6354 kWp (50°C) ArraPy operatingVcharacterisstics (50°Cy) sU mtpp 659 VTRII mppA9635 A L
Total Arrays global power Nominal (STC) 14000 kWp Total 32184 modules
Module area 71609 m² Cell area 63863 m²
Inverter Model PVS-100-TL
Original PVsyst database Manufacturer ABB
Characteristics Operating Voltage 360-1000 V Unit Nom. Power 100 kWac
Sub-array "Sub-array #1" Nb. of inverters 56 units Total Power 5600 kWac
Pnom ratio 1.25
Sub-array "Sub-array #2" Nb. of inverters 56 units Total Power 5600 kWac
Pnom ratio 1.25
Total Nb. of inverters 112 Total Power 11200 kWac
|
PV PArray loss Vfactors syst TRIAL
Array Soiling Losses Loss Fraction 2.0 %
Thermal Loss factor Uc (const) 29.0 W/m²K Uv (wind) 0.0 W/m²K / m/s
Wiring Ohmic Loss Array#1 0.60 mOhm Loss Fraction 0.8 % at STC Array#2 0.60 mOhm Loss Fraction 0.8 % at STC Global Loss Fraction 0.8 % at STC
Serie Diode Loss Voltage Drop 0.7 V Loss Fraction 0.1 % at STC
|
PVSYST V6.88
|
|
19/05/22
|
Page 2/5
|
Grid-Connected System: Simulation parameters
Module Quality Loss Loss Fraction 2.0 %
Module Mismatch Losses Loss Fraction 1.0 % at MPP
Strings Mismatch loss Loss Fraction 0.10 %
Incidence effect (IAM): User defined profile
UnaPvailability ofVthe systemsy3.6 sdays, 3 petriods TRTime frIactionA1.0 % L PVsyst TRIAL PVsyst TRIAL
PVsyst TRIAL
|
0°
|
25°
|
45°
|
60°
|
65°
|
70°
|
75°
|
80°
|
90°
|
1.000
|
1.000
|
0.995
|
0.962
|
0.936
|
0.903
|
0.851
|
0.754
|
0.000
|
PVSYST V6.88
19/05/22
Page 3/5
Grid-Connected System: Main results
Project : BLUESCOPE
Simulation variant : BLUESCOPE 14MWP MÁI ĐÔNG_TÂY
Main system parameters System type No 3D scene defined, no shadings PV Field Orientation 2 orientations Tilt/Azimuth = 10°/-90° and 10°/90°
PV modules Model LR4-72 HPH 435 M Pnom 435 Wp
PV Array Nb. of modules 32184 Pnom total 14000 kWp
Inve Prter VsysMod tel PVS-1 T00-TL RIPnom A100 kW a Lc
Inverter pack Nb. of units 112.0 Pnom total 11200 kW ac
User's needs Unlimited load (grid)
Main simulation results
System Production Produced Energy 20510 MWh/year Specific prod. 1465 kWh/kWp/year
Performance Ratio PR 82.42 %
Normalized productions (per installed kWp): Nominal power 14000 kWp Performance Ratio PR
|
|
Lc : Collection Loss (PV-array losses) 0.74 kWh/kWp/day Ls : System Loss (inverter, ...) 0.12 kWh/kWp/day
|
|
|
:
|
P ed
|
useful energy
|
rt
|
pu
|
4.
|
01 kWh/kWp/day
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
s
|
|
|
6
Yf
roduc
(inve
er out
t)
[kWh/kWp/day]
5
V
P
s
y
s
t
4
Energy
3
Normalized
2
1
0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
1.0
0.9
0.8
T
R
Performance Ratio PR
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
PR : Performance Ratio (Yf / Yr) : 0.824
L
A
I
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
BLUESCOPE 14MWP MÁI ĐÔNG_TÂY
|
GlobHor
kWh/m²
|
DiffHor
kWh/m²
|
T_Amb
°C
|
GlobInc
kWh/m²
|
GlobEff
kWh/m²
|
EArray
MWh
|
E_Grid
MWh
|
PR
|
January
|
149.1
|
59.12
|
26.12
|
147.9
|
141.2
|
1765
|
1730
|
0.835
|
February
|
149.4
|
64.83
|
26.90
|
148.4
|
141.9
|
1762
|
1728
|
0.832
|
March
|
164.8
|
76.65
|
28.31
|
163.6
|
156.6
|
1926
|
1889
|
0.825
|
April
|
146.8
|
75.70
|
29.03
|
145.7
|
139.2
|
1712
|
1603
|
0.786
|
May
|
156.3
|
77.31
|
28.59
|
155.2
|
148.2
|
1828
|
1793
|
0.825
|
June
|
157.8
|
73.92
|
27.60
|
156.7
|
149.7
|
1860
|
1825
|
0.832
|
July
|
161.4
|
81.31
|
27.44
|
160.2
|
152.9
|
1909
|
1873
|
0.835
|
August
|
159.2
|
80.44
|
27.29
|
158.2
|
151.2
|
1884
|
1849
|
0.835
|
September
|
134.9
|
79.22
|
26.67
|
133.7
|
127.5
|
1594
|
1563
|
0.835
|
October
|
142.0
|
78.59
|
26.75
|
140.7
|
134.1
|
1680
|
1649
|
0.837
|
November
|
137.4
|
69.31
|
26.35
|
136.3
|
129.9
|
1633
|
1604
|
0.840
|
December
|
131.8
|
58.75
|
26.11
|
130.8
|
124.7
|
1563
|
1405
|
0.767
|
Year
|
1791.0
|
875.14
|
27.26
|
1777.4
|
1697.2
|
21116
|
20510
|
0.824
|
PVsysBalancestand main Tresults